Scope
1.1 This test method covers the oxidation stability of lubricants by thin-film oxygen uptake (TFOUT) Catalyst B. This test method evaluates the oxidation stability of petroleum products, and it was originally developed as a screening test to indicate whether a given re-refined base stock could be formulated for use as automotive engine oil (see Test Method D 4742
1.2 The applicable range of the induction time is from a few minutes up to several hundred minutes or more. However, the range of induction times used for developing the precision statements in this test method was from 40 to 280 min.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Significance and Use
This test method was originally developed to evaluate oxidation stability of lubricating base oils combined with additives chemistries similar to those found in gasoline engine oils and service.
This test method is useful for screening formulated oils before engine tests. Within similar additive chemistries and base oil types, the ranking of oils in this test appears to be predictive of ranking in certain engine tests. When oils having different additive chemistries or base oil type are compared, results may or may not reflect results in engine tests. Only gasoline engine oils were used in generating the precision statements in this test method.
Keywords
oxidation stability; sequence IIIE engine simulation; TFOUT; Lubricants; Oxidation stability; Thin-film oxygen uptake (TFOUT); ICS Number Code 75.100 (Lubricants, industrial oils and related products)
To find similar documents by ASTM Volume:
05.03 (Petroleum Products and Lubricants (III): D6138 - D6971)
05.04 (Petroleum Products and Lubricants (IV): D6973 - latest)
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-D7098-08
Revision Level
2008 EDITION
Status
Superseded
Modification Type
Revision
Publication Date
Oct. 15, 2008
Document Type
Test Method
Page Count
10 pages
Committee Number
D02.09.0G