ASTM-D93 Historical Revision Information
Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester

ASTM-D93 - 2000 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
ORDER

Scope

1.1 This test method covers the determination of the flash point of petroleum products in the temperature range from 40 to 360oC by a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus.

Note 1--Flash point determination as above 250oC can be performed, however, the precisions have not been determined above this temperature. For residual fuels, precisions have not been determined for flash points above 100oC.

1.2 Procedure A is applicable to distillate fuels (diesel, kerosene, heating oil, turbine fuels), new lubricating oils, and other homogeneous petroleum liquids not included in the scope of Procedure B.

1.3 Procedure B is applicable to residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film under test conditions, or are petroleum liquids of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of Procedure A.

Note 2--Liquids having kinematic viscosities less than 5.5 mm 2/s (cSt) at 40oC (104oF), do not contain suspended solids, or do not have a tendency to form a surface film while under test conditions, can be tested in accordance with Test Method D56.

1.4 This test method is applicable for the detection of contamination of relatively nonvolatile or nonflammable materials with volatile or flammable materials.

1.5 The values stated in SI units shall be regarded as the standard. The values given in parentheses are provided for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see 6.4, 7.1, 9.3, 9.4, 11.1.2, 11.1.4, and 12.1.2

Keywords

automated flash point; automated Pensky-Martens closed cup; flammability; flash point; Pensky-Martens closed cup

To find similar documents by ASTM Volume:

05.01 (Petroleum Products and Lubricants (I): D56 - D3710)

To find similar documents by classification:

13.220.40 (Ignitability and burning behaviour of materials and products)

75.080 (Petroleum products in general)

75.160.20 (Liquid fuels Including gasoline, diesel, kerosene, etc.)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D93-00

Revision Level

2000 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Aug. 10, 2000

Document Type

Test Method

Page Count

16 pages

Committee Number

D02.08