This specification covers exterior windows, glazed curtain walls, doors and impact protective systems used in buildings located in geographic regions that are prone to hurricanes. The test specimens shall be Fenestration assemblies, and impact protective systems; which shall be tested using the large missile test, and small missile test. The air pressure cycling, missiles, and impact location are also detailed.

ORDER

Scope

1.1 This specification covers exterior windows, glazed curtain walls, doors, and impact protective systems used in buildings located in geographic regions that are prone to hurricanes.

1.2 This specification provides the information required to conduct Test Method E 1886.

1.3 Qualification under this specification provides a basis for judgment of the ability of applicable elements of the building envelope to remain unbreached during a hurricane; thereby minimizing the damaging effects of hurricanes on the building interior and reducing the magnitude of internal pressurization. While this standard was developed for hurricanes, it may be used for other types of similar windstorms capable of generating windborne debris.

1.4 This specification provides a uniform set of guidelines based upon currently available information and research. As new information and research becomes available it will be considered.

1.5 All values are stated in SI units and are to be regarded as standard. Values given in parentheses are for information only. Where certain values contained in reference documents cited and quoted herein are stated in inch-pound units they must be converted by the user.

1.6 The following precautionary statement pertains only to the test method portion, Section 5, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. ^REFERENCE:

ASTM Standards:

C 719 Test Method for Adhesion and Cohesion of Elastomeric Joint Sealants Under Cyclic Movement (Hockman Cycle)

C 1135 Test Method for Determining Tensile Adhesion Properties of Structural Sealants

D 3575 Test Methods for Flexible Cellular Materials Made From Olefin Polymers

E 631 Terminology of Building Constructions

E 1886 Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials

ASCE Standard:

ASCE 7 American Society of Civil Engineers Minimum Design Loads for Buildings and Other Structures

Other Standards:

International Residential Code 2000

^KEYWORDS: building envelope; curtain walls; cyclic pressure loading; doors; fenestration; hurricanes; impact protective systems; missile impact; windborne debris; windows; windstorms ^DOI: 10.1520/E1996-09 ^INDEX TERMS: Doors/door assemblies--specifications; Exterior doors--specifications; Exterior windows--specifications; Performance--building materials/applications (specifications); Windows/window assemblies--specifications; Curtain walls; Glazed curtain walls; Hurricanes; Storm shutters; Windborne debris ^STATUS: Dn Cn Sn Nn My ^APPROVAL: 20090401 ^PAGES: 13 ^COMMITTEE: E06 ^SUBCOMMITTEE: 5100 ^BOS: 04.12 ^ORGINFO: ^ACTION: STD_REVISION ^MISCPUB: ^PDESIG: E1996 ^PYEAR: 2009 ^CLASS: Specification

Keywords

building envelope; curtain walls; cyclic pressure loading; doors; fenestration; hurricanes; impact protective systems; missile impact; windborne debris; windows; windstorms, Doors/door assemblies--specifications; Exterior doors--specifications; Exterior windows--specifications; Performance--building materials/applications (specifications); Windows/window assemblies--specifications; Curtain walls; Glazed curtain walls; Hurricanes; Storm shutters; Windborne debris; ICS Number Code 91.060.10 (Walls. Partitions. Facades); 91.060.50 (Doors and windows)

To find similar documents by ASTM Volume:

04.11 (Building Constructions (I): E72 - E2110)

To find similar documents by classification:

91.060.10 (Walls. Partitions. Façades)

91.060.50 (Doors and windows Including doorsets, their components, blinds, shutters Door and window hardware, see 91.190)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1996-09

Revision Level

2009 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

April 1, 2009

Document Type

Specification

Page Count

12 pages

Committee Number

E06.51