Scope
1.1 This guide covers procedures for determining the energy-differential fluence spectra of neutrons used in radiation-hardness testing of electronic semiconductor devices. The types of neutron sources specifically covered by this guide are fission or degraded energy fission sources used in either a steady-state or pulse mode.
1.2 This guide provides guidance and criteria that can be applied during the process of choosing the spectrum adjustment methodology that is best suited to the available data and relevant for the environment being investigated.
1.3 This guide is to be used in conjunction with Guide E720 to characterize neutron spectra and is used in conjunction with Practice E722 to characterize damage-related parameters normally associated with radiation-hardness testing of electronic-semiconductor devices.
Note 1: Although Guide E720 only discusses activation foil sensors, any energy-dependent neutron-responding sensor for which a response function is known may be used (1).2
Note 2: For terminology used in this guide, see Terminology E170.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Significance and Use
4.1 It is important to know the energy spectrum of the particular neutron source employed in radiation-hardness testing of electronic devices in order to relate radiation effects with device performance degradation.
4.2 This guide describes the factors which must be considered when the spectrum adjustment methodology is chosen and implemented. Although the selection of sensors (foils) and the determination of responses (activities) is discussed in Guide E720, the experiment should not be divorced from the analysis. In fact, it is advantageous for the analyst conducting the spectrum determination to be closely involved with the design of the experiment to ensure that the data obtained will provide the most accurate spectrum possible. These data include the following : (1) measured responses such as the activities of foils exposed in the environment and their uncertainties, (2) response functions such as reaction cross sections along with appropriate correlations and uncertainties, (3) the geometry and materials in the test environment, and (4) a trial function or prior spectrum and its uncertainties obtained from a transport calculation or from previous experience.
Keywords
neutron sensors; neutron spectra; radiation-hardness testing; spectrum adjustment ;
To find similar documents by ASTM Volume:
12.02 (Nuclear (II), Solar, and Geothermal Energy)
To find similar documents by classification:
83.140.10 (Films and sheets Including plates)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-E721-16
Revision Level
2016 EDITION
Status
Superseded
Modification Type
Revision
Publication Date
Dec. 1, 2016
Document Type
Guide
Page Count
12 pages
Committee Number
E10.07