ASTM-F448 Historical Revision Information
Test Method for Measuring Steady-State Primary Photocurrent

ASTM-F448 - 2011 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Measuring Steady-State Primary Photocurrent
ORDER

Scope

1.1 This test method covers the measurement of steady-state primary photocurrent, Ipp, generated in semiconductor devices when these devices are exposed to ionizing radiation. These procedures are intended for the measurement of photocurrents greater than 109 A·s/Gy(Si or Ge), in cases for which the relaxation time of the device being measured is less than 25 % of the pulse width of the ionizing source. The validity of these procedures for ionizing dose rates as great as 108Gy(Si or Ge)/s has been established. The procedures may be used for measurements at dose rates as great as 1010Gy(Si or Ge)/s; however, extra care must be taken. Above 108Gy/s, the package response may dominate the device response for any device. Additional precautions are also required when measuring photocurrents of 109 A·s/Gy(Si or Ge) or lower.

1.2 Setup, calibration, and test circuit evaluation procedures are also included in this test method.

1.3 Because of the variability between device types and in the requirements of different applications, the dose rate range over which any specific test is to be conducted is not given in this test method but must be specified separately.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

PN Junction DiodeThe steady-state photocurrent of a simple p-n junction diode is a directly measurable quantity that can be directly related to device response over a wide range of ionizing radiation. For more complex devices the junction photocurrent may not be directly related to device response.

Zener Diode In this device, the effect of the photocurrent on the Zener voltage rather than the photocurrent itself is usually most important. The device is most appropriately tested while biased in the Zener region. In testing Zener diodes or precision voltage regulators, extra precaution must be taken to make certain the photocurrent generated in the device during irradiations does not cause the voltage across the device to change during the test.

Bipolar TransistorAs device geometries dictate that photocurrent from the base-collector junction be much greater than current from the base-emitter junction, measurements are usually made only on the collector-base junction with emitter open; however, sometimes, to obtain data for computer-aided circuit analysis, the emitter-base junction photocurrent is also measured.

Junction Field-Effect DeviceA proper photocurrent measurement requires that the source be shorted (dc) to the drain during measurement of the gate-channel photocurrent. In tetrode-connected devices, the two gate-channel junctions should be monitored separately.

Insulated Gate Field-Effect DeviceIn this type of device, the true photocurrent is between the substrate and the channel, source, and drain regions. A current which can generate voltage that will turn on the device may be measured by the technique used here, but it is due to induced conductivity in the gate insulator and thus is not a junction photocurrent.

Keywords

hardness assurance; ionizing radiation; photocurrent; primary photocurrent; semiconductor testing; Calorimeter; Current measurement--semiconductors; Electrical conductors (semiconductors); Hardness assurance; Insulated gate field-effect (semiconductor) devices; Ionizing radiation; Irradiance/irradiation--semiconductors; Junction field-effect (semiconductor) devices; Peak photocurrent; Primary photocurrent; Radiation exposure--electronic components/devices; Semiconductor device testing; Thermoluminescent dosimeter (TLD); Transistors; Zener diodes; ICS Number Code 31.260 (Optoelectronics. Laser equipment)

To find similar documents by ASTM Volume:

10.04 (Electronics; Declarable Substances in Materials; 3D Imaging Systems)

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

31.260 (Optoelectronics. Laser equipment Including photoelectric tubes and cells)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-F448-11

Revision Level

2011 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

July 1, 2011

Document Type

Test Method

Page Count

7 pages

Committee Number

F01.11