ASTM-F710 Historical Revision Information
Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring

ASTM-F710 - 2008 EDITION - SUPERSEDED -- See the following: ASTM-E1907
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This practice covers the procedure for determining the acceptability of concrete floors for the installation of resilient flooring. It also includes suggestions for ensuring that the constructed concrete floor is acceptable for such installations but does not cover tests for adequacy of the concrete floor to perform structural requirements. A permanent, effective moisture vapor retarder, of the specified thickness and permeance, is required under all on- or below-grade concrete floors. Concrete floors for resilient floorings should be permanently dry, clean, smooth, structurally sound, and free of substances that may prevent adhesive bonding. Surface cracks, grooves, depression, control joints or other non-moving joints, and other irregularities should be filled or smoothed with latex patching or a recommended underlayment compound. The surface of the floor should be cleaned by scraping, brushing, vacuuming, or any other method. All concrete slabs should be tested for moisture regardless of age or grade level while all concrete floors should be tested for pH before installing resilient flooring.

ORDER

Scope

1.1 This practice covers the determination of the acceptability of a concrete floor for the installation of resilient flooring.

1.2 This practice includes suggestions for the construction of a concrete floor to ensure its acceptability for installation of resilient flooring.

1.3 This practice does not cover the adequacy of the concrete floor to perform its structural requirements.

1.4 This practice covers the necessary preparation of concrete floors prior to the installation of resilient flooring.

1.5 This practice does not supersede in any manner the resilient flooring or adhesive manufacturer's written instructions. Consult the individual manufacturer for specific recommendations.

1.6 Although carpet tiles, carpet, wood flooring, coatings, films, and paints ae not specifically intended to be included in the category of resilient floor coverings, the procedures included in this practice may be useful for preparing concrete floors to receive such finishes.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 5.1, 7.1.1, and 7.1.2 for specific warning statements.

1.8 The values stated in inch-pound units are to be regarded as standard. The values in parentheses are mathematical conversions to SI units and are provided for information only.

Keywords

adhesive removers; cement; concrete floors; installation; moisture; moisture vapor emissions; pH testing; preparation; resilient flooring; rubber; slabs; Acceptability; Adhesive removers; Flooring/floor covering systems (concrete); Installation--flooring applications; Moisture vapor processing; Resilient flooring; Specimen preparation (general); Subflooring; Terrazzo flooring

To find similar documents by ASTM Volume:

15.04 (Soaps and Other Detergents; Polishes; Leather; Resilient Floor Coverings)

To find similar documents by classification:

91.060.30 (Ceilings. Floors. Stairs Including screeds, ramps, etc.)

97.150 (Non-textile floor coverings Textile floor coverings, see 59.080.60)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-F710-08

Revision Level

2008 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Jan. 1, 2008

Document Type

Practice

Page Count

6 pages

Committee Number

F06.40