ASTM-F1190 Historical Revision Information
Standard Guide for Neutron Irradiation of Unbiased Electronic Components

ASTM-F1190 - 1993 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Neutron Irradiation of Unbiased Electronic Components
ORDER

Scope

1.1 This practice applies to the exposure of unbiased silicon (Si) or gallium arsenide (GaAs) semiconductor components to neutron radiation from a nuclear reactor source. Only the conditions of exposure are addressed in this practice. The effects of radiation on the test sample should be determined using appropriate electrical test methods.

1.2 System and subsystem exposures and test methods are not included in this practice.

1.3 This practice is applicable to irradiations conducted with the reactor operating in either the pulsed or steady-state mode. The practical limits for neutron fluence ([phi]eq,1MeV,Si or [phi]eq,1MeV,GaAs) in semiconductor testing range from approximately 10 to 10 16 n/cm .

1.4 This practice addresses those issues and concerns pertaining to irradiations with neutrons of energies greater than 10 keV.

1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Destructive testing-semiconductors; Dosimetry; Electrical conductors-semiconductors; Equivalent monoenergetic neutron fluence; Exposure tests; Fast burst reactors (FBR); Gallium arsenide; Gamma radiation; Germanium-semiconductor applications; Irradiance/irradiation-semiconductors; MeV equivalent fluence; Neutron radiation; Nickel; Radiation exposure-electronic components/devices; Semiconductor wafer; Silicon-semiconductor applications; Sulfur; Thermal neutron radiation; Thermoluminescent detector (TLD); TRIGA-type reactors; neutron irradiation of unbiased electronic components, practice; ICS Number Code 31.080.01 (Semi-conductor devices in general)

To find similar documents by ASTM Volume:

10.04 (Electronics; Declarable Substances in Materials; 3D Imaging Systems)

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

31.020 (Electronic components in general Magnetic components, see 29.100.10)

31.080.01 (Semiconductor devices in general)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-F1190-93

Revision Level

1993 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Aug. 15, 1993

Document Type

Practice

Page Count

5 pages

Committee Number

F01.11